NCC 2019 Façade Calculator and Speckel

The NCC 2019 Volume One façade calculator is a tool used in Australia's National Construction Code (NCC). It helps assess the thermal performance of a building's façade, considering factors like glazing, insulation, and shading. It aids in ensuring compliance with energy efficiency standards.

While a common currency for building certifiers to address NCC compliance, the NCC 2019 Volume One façade calculator is not required, nor does it meet Section J requirements. The statement below summarises that provided with the NCC 2019 Volume One façade calculator and clarifies it is not considered legal or professional advice.

More specifically, the NCC 2019 Volume One façade calculator only meets the partial requirements of Specification J1.5a Calculation of U-Value and solar admittance as it does not undertake AS/NZ 4859.2 calculations as per J1.2 Thermal construction — general.

Specification J1.5 a - (b) The Total system U-Value of the wall component of a wall-glazing construction must be calculated as the inverse of the Total R-Value, including allowance for thermal bridging, in accordance with— (i) AS/NZS 4859.2;

J1.2 Thermal Construction - (e) The required Total R-Value and Total System U-Value, including allowance for thermal bridging, must be— (i) calculated in accordance with AS/NZS 4859.2 for a roof or floor; or