External Surfaces

Convection Method
Configure the Convection Method to determine fixed or dynamic inputs.
Fixed value
Configure a Convection Coefficient W/(m² K). Wall Default 10 W/(m² K).
Wind-driven (EN 15026)
Configure a Wind-driven (EN 15026) that is derived as a convective-only film from the climate wind speed.
Vapour Method
Configure the Vapour Method to determine fixed or dynamic inputs.
Fixed value
Configure a constant Vapour Transfer Coefficient kg/(m² s Pa). Wall default 7.65e-8 kg/(m² s Pa).
Wind-driven (EN 15026)
Configure a Wind-driven (Lewis) that is derived as a vapour transfer coefficient β from the wind film.
Coating Method
A vapour-retarding coating is a liquid-applied material used to slow down or limit the movement of water vapour through building surfaces like concrete slabs, walls, or thermal insulation. It prevents moisture from entering structural cavities and causing condensation, mould, or material decay.
None
Configure a vapour-retarding coating on the exterior surface. Default = no coating.
Fixed sd
Configure a vapour-retarding coating on the exterior surface. Select from dropdown or specify specific value.
Solar Absorptivity
Configure the Short-wave (solar) absorptivity of the exterior finish. Solar absorptivity (or solar absorptance) is the fraction of total incident solar radiation absorbed by a material, expressed as a decimal value between 0 and 1. Default 0.5, representing a mid coloured wall.
Long-Wave Emissivity
Configure the Long-wave emissivity, a measure of how efficiently a surface emits thermal or infrared radiation compared to an ideal blackbody, typically ranging from 0 to 1. Default 0.90.
Ground Emissivity
Configure the long-wave emissivity of the ground half-view typically ranges from 0.90 to 0.98 for most natural surfaces. Default 0.90. Ground reflectivity set as the inverse.
Cloud Index
Configure the Cloud Index, the sky cloud-cover fraction with 0 = clear sky, 1 fully overcast. Drives the long-wave sky exchange. Default 0.66.