> For the complete documentation index, see [llms.txt](https://docs.betterbuilding.io/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://docs.betterbuilding.io/support-and-training/other-support/testing-and-verification/iso-10077-2-window-frame-validation-report.md).

# ISO 10077-2 Window Frame Validation Report

Software Version: Better Building Thermx Solver 1.0 I Date of Testing: 28/10/26  I Report Version: 1.0 I Prepared by Darren O'Dea

## 1. Purpose and Scope <a href="#user-content-1-purpose-and-scope" id="user-content-1-purpose-and-scope"></a>

### **1.1 Introduction**

This report records how the two-dimensional solver behind the Better Building detail tool performs against the validation cases of ISO 10077-2:2017 for window frames, shutter boxes and the frame and glazing junction. It is written for third-party assurance: each case states how the standard's figure was modelled, every judgement the figure leaves to the modeller, the result against the standard's value, and the same model solved in LBNL THERM 7.8 as an independent check.

he detail tool solves with Better Building Thermx Solver 1.0, an independent finite-element solver  and checked against THERM 7.8 itself. Window frames are reported separately in the ISO 10077-2 Window Frame Validation Report (version 1.0), and the ISO 14683 junctions in the ISO 10211 / ISO 14683 / ISO 10077-2 thermal-bridge validation report (version 2.0).

Two references are used:

1. **The standard's values:** ISO 10077-2:2017 Annex I, Tables I.3 and I.4, the mean of a round robin of calculations (June 2000), with the standard deviation, and the 3 % acceptance band of 5.3.
2. **THERM 7.8 itself:** every case is exported from the detail tool as a THERM file and solved in the installed THERM 7.8.80.0, so the report also shows whether the Better Building Thermx Solver 1.0 gives THERM's own answer on the same model.

### **1.2 The standard**

* **Scope of the validation (5.3, Annex I.1).** A program used to calculate the thermal transmittance of frames is validated by calculating the cases of Annex I (single equivalent thermal conductivity method for cavities) or of Annexes G and H (radiosity method). It passes when the two-dimensional thermal coupling coefficient L2D is within 3 % of the tabulated value for every case (about 5 % on U and Ψ).
* **Which annex applies.** THERM's CEN frame-cavity model is the single equivalent thermal conductivity method of 6.4.3 (Appendix C compares it with the standard point by point), so **Annex I** is the validation that applies.
* **Frame transmittance (Annex F.1).** The glazing is replaced by an insulation panel of λ = 0.035 W/(m K) with a visible length of at least 190 mm and an adiabatic end. Uf = (L2D - Up bp) / bf, with Up the panel's one-dimensional transmittance, bp its visible length and bf the frame's projected width.
* **Linear thermal transmittance (Annex F.2).** With the glazing in place, Ψ = L2D - Uf bf - Ug bg.
* **L2D.** The heat flow per metre through the section divided by the temperature difference between the interior and exterior environments.

### **1.3 Case overview**

**Table 1.1: Cases**

| Case | Annex I figure   | Detail                                                  | Quantity checked                | Reference value |
| ---- | ---------------- | ------------------------------------------------------- | ------------------------------- | --------------- |
| W-1  | I.1              | Aluminium frame with thermal break and insulation panel | L2D (Uf)                        | Table I.3       |
| W-2  | I.2              | Aluminium clad wood frame                               | L2D (Uf)                        | Table I.3       |
| W-3  | I.3              | PVC frame with steel reinforcement                      | L2D (Uf)                        | Table I.3       |
| W-4  | I.4              | Wood frame                                              | L2D (Uf)                        | Table I.3       |
| W-5  | I.5              | Roof window frame                                       | L2D (Uf)                        | Table I.3       |
| W-6  | I.6              | Sliding window frame                                    | L2D (Uf)                        | Table I.3       |
| W-7  | I.7              | Fixed PVC frame                                         | L2D (Uf)                        | Table I.3       |
| W-8  | I.8              | PVC roller shutter box                                  | L2D (U)                         | Table I.3       |
| W-9  | I.9              | PVC shutter profile                                     | L2D (U)                         | Table I.3       |
| W-10 | I.10             | Wood frame with glazing (conventional edge seal)        | L2D and Ψ                       | Table I.4       |
| T    | All of the above | Each model solved in THERM 7.8.80.0                     | U, length and error-energy norm | THERM 7.8       |

### **1.4 Pass criteria**

| Verdict          | Meaning                                                                                                                                                                        |
| ---------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ |
| **Pass**         | L2D within 3 % of the standard's value (5.3).                                                                                                                                  |
| **Pass (THERM)** | Thermx equals THERM 7.8 at THERM's displayed precision, and THERM 7.8's own result is outside the 3 % band: the difference from the standard is THERM 7.8's, recorded as such. |
| **Fail**         | Outside the band, and THERM 7.8 gives a different answer on the same model.                                                                                                    |

Equality with THERM 7.8 is judged on the U-factor dialog's displayed precision: U to 4 decimals and the tag length to the whole millimetre.

## 2. Software Configuration, General Notes <a href="#user-content-2-software-configuration-general-notes" id="user-content-2-software-configuration-general-notes"></a>

**Table 2.1: Configuration**

| Parameter              | Value                                                                                                                                                                                                                                            |
| ---------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ |
| Engine                 | Better Building Thermx Solver 1.0                                                                                                                                                                                                                |
| Pipeline               | The detail drawing (zones, materials, boundary conditions, U-factor tags) is mapped to a THERM model, THERM's boundary generation runs, then the mesher, CONRAD and THERM's post-processing; the same path every design in the detail tool takes |
| Mesh                   | THERM's quadtree mesher, mesh parameter 6, error estimator on, error-energy-norm limit 10 %, at most 3 refinement passes (THERM 7.8's pinned settings, the settings the NFRC Simulation Manual requires)                                         |
| Fixed temperatures     | THERM's constant-temperature boundary condition, held by CONRAD's penalty method                                                                                                                                                                 |
| Surface resistances    | THERM convection boundary conditions with h = 1 / R                                                                                                                                                                                              |
| Temperatures at points | The finite-element solution interpolated within THERM's elements at each point (not a resampled raster)                                                                                                                                          |
| Heat flow              | Read from THERM U-factor tags as THERM reports them: U x length x delta T                                                                                                                                                                        |
| Fidelity to THERM 7.8  | 254 of 257 regression-corpus models reproduce every reported value of THERM 7.8 end to end (the other 3 differ by one float32 step in the stored error-energy norm); 325 of 325 THERM solves reproduced from THERM's own solver input            |

## 3. Method of Assessment <a href="#user-content-3-method-of-assessment" id="user-content-3-method-of-assessment"></a>

### **3.1 Modelling each figure**

1. **Geometry.** Each Annex I figure is drawn from its dimension chains. The 2017 figures are 300 dpi scans drawn to scale, so every chain was also measured on the drawing's own scale (between 5.91 and 22.69 pixels per millimetre, the same horizontally and vertically within each figure); every outline falls on a whole or half millimetre. Where a 2017 chain disagrees with its drawing, the 2003 edition's Figure D.n (the same round-robin case) was consulted. The finished model was checked by drawing it over the figure.
2. **Materials.** Table I.2, by the figure's key letters; where the key labels only one of several identically hatched parts, the same hatching is read as the same material. Emissivity 0.9 on all surfaces (4.1).
3. **Cavities.** Each air space is classified by 6.4.3: closed, or open through a slit not over 2 mm, is unventilated (CEN); open through a slit over 2 and not over 10 mm, or a small groove, is slightly ventilated (CEN ventilated); wider openings are surfaces taking Rse or Rsi on their developed length. Cavities joined by a connection not over 2 mm, or with one dimension not over 2 mm, are separate cavities (Figure 13).
4. **Boundaries.** Cut planes adiabatic (5.2); the panel's far end adiabatic (Annex F.1); Rse 0.04 on exterior faces; Rsi 0.13 on interior faces and 0.20 in internal corners over b = d, at most 30 mm (Annex E, Table E.1 and Figure E.1).
5. **Read-out.** The interior faces carry the U-factor tag Frame; THERM reports U over the tag's total length, and L2D = U x length. The exterior faces carry the tag Exterior, so the heat flow in and out can be compared (Section 14.2).

### **3.2 Solving**

Each case is solved through the whole pipeline a user's design runs through (Table 2.1), which fails if L2D is outside the case's tolerance or if Better Building Thermx Solver 1.0 Frame U differs from THERM 7.8's recorded value at 4 decimals.

### **3.3 Independent check in THERM 7.8**

Each case was exported from the detail tool as THERM files, opened in THERM 7.8.80.0 and calculated by a scripted harness that operates THERM's own interface . The harness records THERM's dialogs (U-factors in every projection, the error-energy norm, warnings, Min/Max temperatures) as JSON and screenshots, and restores THERM's settings and libraries after each file.&#x20;

### **3.4 Surface resistance in internal corners**

The figures mark only internal (C) and external (B) surfaces, not where Annex E's corner value applies. Case W-4 was solved both ways to settle how the round robin applied it: with Rsi 0.20 in the internal corners L2D is 0.3468 (+0.2 %), with 0.13 throughout 0.3542 (+2.4 %), against 0.346. Every case therefore applies the corner value.

## 4. Case W-1: Aluminium Frame with Thermal Break (Figure I.1) <a href="#user-content-4-case-w-1-aluminium-frame-with-thermal-break-figure-i1" id="user-content-4-case-w-1-aluminium-frame-with-thermal-break-figure-i1"></a>

### **4.1 Scenario Description**

<img src="https://2129322768-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FfKJnzF2TwHA3APPbiCpF%2Fuploads%2FJC5JP9LdeKHKvGBT7mvj%2FModel%20of%20Figure%20I.1?alt=media&amp;token=7bc7b5a7-74fd-4182-a4aa-170e49fb015f" alt="Model of Figure I.1" height="302" width="610">

**Table 4.1: Case W-1**

| Parameter          | Value                                                                                                                                                                                                                                  |
| ------------------ | -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| Geometry           | Frame 110 mm wide (bf), 63 mm deep; 2 mm aluminium walls; four polyamide strips held by 2 mm claws                                                                                                                                     |
| Materials          | h aluminium 160, e polyamide 6.6 with 25 % glass fibre 0.3, d EPDM 0.25, a panel 0.035                                                                                                                                                 |
| Model              | 82 polygons: 60 solid, 22 cavities                                                                                                                                                                                                     |
| Cavities           | 21 unventilated: every closed chamber; the 2 mm pockets beside each strip, the 2 mm notch under the tube and the 2 mm passage behind the exterior slit as separate cavities (Figure 13). 1 slightly ventilated: the 5 mm exterior slit |
| Panel              | 28 mm, set in 15 mm, visible length 190 mm, Up 1.031 W/(m2 K)                                                                                                                                                                          |
| Corners (Rsi 0.20) | The 10 mm step at x = 40; the 25 mm rise of the frame above the panel                                                                                                                                                                  |
| Judgements         | 2017's key labels one strip e and one gasket d; the same hatching is read as the same material                                                                                                                                         |

### **4.2 Results**

**Table 4.2: Case W-1**

| Quantity          | Standard (s.d.) | Thermx               | Difference | THERM 7.8            |
| ----------------- | --------------- | -------------------- | ---------- | -------------------- |
| L2D W/(m K)       | 0.550 (0.007)   | 0.5408               | -1.7 %     | 0.5408               |
| Uf W/(m2 K)       | 3.22 (0.06)     | 3.135                | -2.6 %     | 3.135                |
| Frame tag         | -               | U 1.6142 over 335 mm | -          | U 1.6142 over 335 mm |
| Error-energy norm | -               | 7.48 %               | -          | 7.48 %               |

{% hint style="success" %}
**Verdict: Pass.**
{% endhint %}

## 5. Case W-2: Aluminium Clad Wood Frame (Figure I.2) <a href="#user-content-5-case-w-2-aluminium-clad-wood-frame-figure-i2" id="user-content-5-case-w-2-aluminium-clad-wood-frame-figure-i2"></a>

### **5.1 Scenario Description**

**Table 5.1: Case W-2**

| Parameter          | Value                                                                                                                                                                 |
| ------------------ | --------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| Geometry           | Frame 110 mm wide (bf), 119 mm deep; softwood frame and sash, 2 mm aluminium cladding with a 6 mm air gap, a 14 x 26 mm box and a 34 x 31 mm profile under the panel  |
| Materials          | b softwood 0.13, h aluminium 160, d EPDM 0.25, a panel 0.035                                                                                                          |
| Model              | 25 polygons: 18 solid, 7 cavities                                                                                                                                     |
| Cavities           | 7 unventilated. The large cavity between frame, sash and profile reaches the exterior only through a 2 mm slit between the two profiles, drawn as a cavity of its own |
| Panel              | 58 mm, visible length 190 mm, Up 0.547 W/(m2 K)                                                                                                                       |
| Corners (Rsi 0.20) | b = d = 19 mm at the frame top and sash face; along the sash face and the panel above it                                                                              |
| Judgements         | 2017's chain labels are clipped in places; every edge measured on the drawing's scale and checked on 2003's Figure D.2                                                |

### **5.2 Results**

**Table 5.2: Case W-2**

| Quantity          | Standard (s.d.) | Thermx               | Difference | THERM 7.8            |
| ----------------- | --------------- | -------------------- | ---------- | -------------------- |
| L2D W/(m K)       | 0.263 (0.001)   | 0.2602               | -1.1 %     | 0.2602               |
| Uf W/(m2 K)       | 1.44 (0.03)     | 1.420                | -1.4 %     | 1.420                |
| Frame tag         | -               | U 0.7699 over 338 mm | -          | U 0.7699 over 338 mm |
| Error-energy norm | -               | 9.86 %               | -          | 9.86 %               |

{% hint style="success" %}
**Verdict: Pass.**
{% endhint %}

## 6. Case W-3: PVC Frame with Steel Reinforcement (Figure I.3) <a href="#user-content-6-case-w-3-pvc-frame-with-steel-reinforcement-figure-i3" id="user-content-6-case-w-3-pvc-frame-with-steel-reinforcement-figure-i3"></a>

### **6.1 Scenario Description**

**Table 6.1: Case W-3**

| Parameter          | Value                                                                                                                                                                                                            |
| ------------------ | ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| Geometry           | Frame 110 mm wide (bf), 83 mm deep; 3 mm PVC walls; a steel C in the frame and a steel L in the sash, 2 mm                                                                                                       |
| Materials          | c PVC 0.17, g steel 50, d EPDM 0.25, a panel 0.035                                                                                                                                                               |
| Model              | 46 polygons: 26 solid, 20 cavities                                                                                                                                                                               |
| Cavities           | 20 unventilated. The frame and sash gap below the middle gasket reaches the exterior through a 1 mm slit, drawn as its own cavity; the 1 mm gaps along each steel's long faces are separate cavities (Figure 13) |
| Panel              | 28 mm, visible length 190 mm, Up 1.031 W/(m2 K)                                                                                                                                                                  |
| Corners (Rsi 0.20) | The 17 mm step at x = 28; the 25 mm rise above the panel                                                                                                                                                         |
| Judgements         | 2017 draws no PVC hatch and its extension lines run through the section: which regions are PVC and which air is read from 2003's Figure D.3                                                                      |

### **6.2 Results**

**Table 6.2: Case W-3**

| Quantity          | Standard (s.d.) | Thermx               | Difference | THERM 7.8            |
| ----------------- | --------------- | -------------------- | ---------- | -------------------- |
| L2D W/(m K)       | 0.424 (0.006)   | 0.4192               | -1.1 %     | 0.4192               |
| Uf W/(m2 K)       | 2.07 (0.06)     | 2.030                | -1.9 %     | 2.030                |
| Frame tag         | -               | U 1.2257 over 342 mm | -          | U 1.2257 over 342 mm |
| Error-energy norm | -               | 7.41 %               | -          | 7.41 %               |

{% hint style="success" %}
**Verdict: Pass.**
{% endhint %}

## 7. Case W-4: Wood Frame (Figure I.4) <a href="#user-content-7-case-w-4-wood-frame-figure-i4" id="user-content-7-case-w-4-wood-frame-figure-i4"></a>

### **7.1 Scenario Description**

**Table 7.1: Case W-4**

| Parameter          | Value                                                                                                                        |
| ------------------ | ---------------------------------------------------------------------------------------------------------------------------- |
| Geometry           | Frame 110 mm wide (bf), 83 mm deep, softwood                                                                                 |
| Materials          | b softwood 0.13, d EPDM 0.25, a panel 0.035                                                                                  |
| Model              | 10 polygons: 7 solid, 3 cavities                                                                                             |
| Cavities           | Unventilated: the slot (6 x 54 mm) and the panel clearance (5 mm). Slightly ventilated: the 5 mm groove open to the exterior |
| Panel              | 28 mm, overlap 15 mm, clearance 5 mm, visible length 190 mm, Up 1.031 W/(m2 K)                                               |
| Corners (Rsi 0.20) | The 17 mm step at x = 26 (b = 17); the 37 mm rise above the panel (b = 30)                                                   |
| Variant            | Solved also with Rsi 0.13 throughout (Section 3.4)                                                                           |

### **7.2 Results**

**Table 7.2: Case W-4**

| Quantity                          | Standard (s.d.) | Thermx               | Difference | THERM 7.8                     |
| --------------------------------- | --------------- | -------------------- | ---------- | ----------------------------- |
| L2D W/(m K)                       | 0.346 (0.001)   | 0.3468               | +0.2 %     | 0.3468                        |
| Uf W/(m2 K)                       | 1.36 (0.01)     | 1.372                | +0.9 %     | 1.372                         |
| Frame tag                         | -               | U 0.9797 over 354 mm | -          | U 0.9797 over 354 mm          |
| Error-energy norm                 | -               | 4.82 %               | -          | 4.82 %                        |
| Variant, Rsi 0.13 throughout: L2D | 0.346           | 0.3542               | +2.4 %     | 0.3542 (U 1.0006 over 354 mm) |

{% hint style="success" %}
**Verdict: Pass** (the variant is also within 3 %, but the corner values match far better).
{% endhint %}

## 8. Case W-5: Roof Window Frame (Figure I.5) <a href="#user-content-8-case-w-5-roof-window-frame-figure-i5" id="user-content-8-case-w-5-roof-window-frame-figure-i5"></a>

### **8.1 Scenario Description**

<img src="https://2129322768-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FfKJnzF2TwHA3APPbiCpF%2Fuploads%2FFrD2vKij7QhQPyCHD9UV%2FModel%20of%20Figure%20I.5?alt=media&amp;token=4a781857-55e2-4c90-a56a-19093f83b1f1" alt="Model of Figure I.5" height="630" width="606">

**Table 8.1: Case W-5**

| Parameter          | Value                                                                                                                                                                                                                                                                                                                                                             |
| ------------------ | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| Geometry           | Drawn as the figure (5.2: sections taken as vertical whatever the window's orientation): panel horizontal, exterior below, interior above and right, the roof on the left; 145 mm high, 90 mm from the wood face to the sash face                                                                                                                                 |
| Materials          | b softwood 0.13, h aluminium 160 (claddings 1 mm), d EPDM 0.25, a panel 0.035                                                                                                                                                                                                                                                                                     |
| Model              | 19 polygons: 11 solid, 8 cavities                                                                                                                                                                                                                                                                                                                                 |
| Cavities           | Unventilated: the gap behind the claddings (closed by the roof), the 1 mm slit between the claddings, the 3 x 20 mm slot under the weather strip, the 2 mm slot beside the hook, the 5 x 28 mm slot at the panel edge. Slightly ventilated: the 3 mm groove open to the interior, the sill cavity (open through a 3 mm slit), the hook cavity (open through 5 mm) |
| Panel              | 24 mm, visible length 190 mm, Up 1.169 W/(m2 K)                                                                                                                                                                                                                                                                                                                   |
| Boundaries         | Roof contacts adiabatic                                                                                                                                                                                                                                                                                                                                           |
| Corners (Rsi 0.20) | The frame face rising 49 mm above the sash top (b = 30); the 7 mm step at x = 77; the sash face rising 56 mm above the panel (b = 30)                                                                                                                                                                                                                             |
| Judgements         | The NOTE gives bf = 89 mm, but every 2017 chain and the drawing's scale give 90 mm (2003's Figure D.5 drew the frame 1 mm narrower); taken as drawn, bf = 90. L2D does not depend on bf                                                                                                                                                                           |

### **8.2 Results**

**Table 8.2: Case W-5**

| Quantity          | Standard (s.d.) | Thermx               | Difference | THERM 7.8            |
| ----------------- | --------------- | -------------------- | ---------- | -------------------- |
| L2D W/(m K)       | 0.408 (0.007)   | 0.4035               | -1.1 %     | 0.4035               |
| Uf W/(m2 K)       | 2.08 (0.08)     | 2.017 (bf 90)        | -3.0 %     | 2.017                |
| Frame tag         | -               | U 1.0294 over 392 mm | -          | U 1.0294 over 392 mm |
| Error-energy norm | -               | 9.75 %               | -          | 9.75 %               |

With bf = 89 mm as the NOTE states, Uf would be 2.04 (-1.9 %).

{% hint style="success" %}
**Verdict: Pass.**
{% endhint %}

## 9. Case W-6: Sliding Window Frame (Figure I.6) <a href="#user-content-9-case-w-6-sliding-window-frame-figure-i6" id="user-content-9-case-w-6-sliding-window-frame-figure-i6"></a>

**9.1 Scenario Description**

![Model of Figure I.6](https://2129322768-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FfKJnzF2TwHA3APPbiCpF%2Fuploads%2Fe9utIrA0UAQl67UoH94l%2FModel%20of%20Figure%20I.6?alt=media\&token=4c4f3fda-5e5f-4420-a646-cc2296cde2dc)

**Table 9.1: Case W-6**

| Parameter          | Value                                                                                                                                                                                                                                                                                                                                                           |
| ------------------ | --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| Geometry           | bf = 95 mm (43 + 52, as the NOTE), 85 mm deep; 2 mm aluminium walls in an interior and an exterior part for frame and sash                                                                                                                                                                                                                                      |
| Materials          | h aluminium 160, k polyamide 0.25 (the frame's thermal break), l rigid PU 0.25 (the two boxes bridging each part's channel), i pile weather stripping 0.14, d EPDM 0.25, a panel 0.035                                                                                                                                                                          |
| Model              | 25 polygons: 12 solid, 13 cavities                                                                                                                                                                                                                                                                                                                              |
| Cavities           | Unventilated: the frame's left and middle cavities, the track and sash cavity, four 2 mm gaps beside the boxes, the 2 mm slot beside the EPDM, four 2 x 2 mm recesses at the piles. Slightly ventilated: the 4 mm pocket under the arm. The gutter under the frame (15 mm wide) is open more than 10 mm: no cavity, its developed surface takes Rse (6.4.3.6.2) |
| Panel              | 25 mm, visible length 190 mm, Up 1.131 W/(m2 K)                                                                                                                                                                                                                                                                                                                 |
| Corners (Rsi 0.20) | The frame's 4 mm rise above the sash top; the sash's 4 mm rise above the panel                                                                                                                                                                                                                                                                                  |
| Judgements         | 2003 keys the sash box l (rigid PU 0.25), 2017 keys it i (pile 0.14); taken as l for both boxes, since pile is drawn with vertical lines elsewhere in the same figure                                                                                                                                                                                           |

### **9.2 Results**

**Table 9.2: Case W-6**

| Quantity          | Standard (s.d.) | Thermx               | Difference | THERM 7.8                                                                                                             |
| ----------------- | --------------- | -------------------- | ---------- | --------------------------------------------------------------------------------------------------------------------- |
| L2D W/(m K)       | 0.659 (0.008)   | 0.6354               | **-3.6 %** | 0.6354                                                                                                                |
| Uf W/(m2 K)       | 4.67 (0.09)     | 4.427                | -5.2 %     | 4.427                                                                                                                 |
| Frame tag         | -               | U 2.1686 over 293 mm | -          | U 2.1686 over 293 mm                                                                                                  |
| Error-energy norm | -               | 11.63 %              | -          | 11.63 %, with THERM's warning "The maximum number of meshing iterations reached before the error target was reached." |

**Investigation.** The model was checked by overlay against the 2017 scan. Every alternative reading the standard allows lowers L2D further: the foot gutter as a cavity rather than exposed, the track cavity split at its 2 mm connections, the sash box as 2017's key has it (pile 0.14: -7.5 %). THERM's cavity radiation term (Appendix C) gives more radiation than the standard's in wide cavities, so it is not the cause. THERM 7.8, solving the identical model, gives the same L2D and the same error-energy norm, and warns that it reached its refinement limit before its 10 % error target.

{% hint style="success" %}
**Verdict: Pass (THERM).** The 3.6 % difference is THERM 7.8's own result on this figure, which Thermx reproduces exactly.
{% endhint %}

## 10. Case W-7: Fixed PVC Frame (Figure I.7) <a href="#user-content-10-case-w-7-fixed-pvc-frame-figure-i7" id="user-content-10-case-w-7-fixed-pvc-frame-figure-i7"></a>

### **10.1 Scenario Description**

![Model of Figure I.7](https://2129322768-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FfKJnzF2TwHA3APPbiCpF%2Fuploads%2Fp8aPBJXSN2jtfn1k2CZi%2FModel%20of%20Figure%20I.7?alt=media\&token=53d97521-debb-421a-8ca4-8c8b6ac3752d)

**Table 10.1: Case W-7**

| Parameter          | Value                                                                                                                                    |
| ------------------ | ---------------------------------------------------------------------------------------------------------------------------------------- |
| Geometry           | bf = 48 mm (31 + 17, as the NOTE), 99 mm deep; 3 mm PVC walls; two sloping walls (3 mm measured square to the wall)                      |
| Materials          | c PVC 0.17, d EPDM 0.25, a panel 0.035                                                                                                   |
| Model              | 20 polygons: 12 solid, 8 cavities                                                                                                        |
| Cavities           | 7 unventilated, all closed, none narrower than 3 mm. 1 slightly ventilated: the 3 mm groove at the foot, open to the exterior            |
| Panel              | 24 mm between 3 mm EPDM gaskets, visible length 190 mm, Up 1.169 W/(m2 K)                                                                |
| Corners (Rsi 0.20) | The 12 mm step at x = 31; the 28 mm rise of the bead above the panel                                                                     |
| Judgements         | The sloping walls carry no dimension: run between the chains' corners. Glazing bead and frame (both c, in contact) taken as one PVC body |

### **10.2 Results**

**Table 10.2: Case W-7**

| Quantity          | Standard (s.d.) | Thermx               | Difference | THERM 7.8            |
| ----------------- | --------------- | -------------------- | ---------- | -------------------- |
| L2D W/(m K)       | 0.285 (0.002)   | 0.2839               | -0.4 %     | 0.2839               |
| Uf W/(m2 K)       | 1.31 (0.03)     | 1.288                | -1.7 %     | 1.288                |
| Frame tag         | -               | U 1.0211 over 278 mm | -          | U 1.0211 over 278 mm |
| Error-energy norm | -               | 4.71 %               | -          | 4.71 %               |

{% hint style="success" %}
**Verdict: Pass.**
{% endhint %}

## 11. Case W-8: PVC Roller Shutter Box (Figure I.8) <a href="#user-content-11-case-w-8-pvc-roller-shutter-box-figure-i8" id="user-content-11-case-w-8-pvc-roller-shutter-box-figure-i8"></a>

### **11.1 Scenario Description**

![Model of Figure I.8](https://2129322768-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FfKJnzF2TwHA3APPbiCpF%2Fuploads%2FLW4hh96t4wJTOvLKMQUl%2FModel%20of%20Figure%20I.8?alt=media\&token=c1275b78-ecad-4ff5-8b11-3e304a429ff0)

**Table 11.1: Case W-8**

| Parameter  | Value                                                                                                                                                                                                                  |
| ---------- | ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| Geometry   | Box 198 mm wide, 177 mm high (bsb); walls 10 mm thick, 1 mm PVC skins and webs around 8 mm chambers; a 15 mm gap where the shutter leaves the box                                                                      |
| Materials  | c PVC 0.17, a insulation 0.035 (L-shaped, inside the box)                                                                                                                                                              |
| Model      | 59 polygons: 21 solid, 38 cavities                                                                                                                                                                                     |
| Cavities   | 37 closed PVC chambers, unventilated. The box cavity, open to the exterior through the 15 mm gap with e1 + e3 over 2 mm: slightly ventilated (Section 11.2). The shutter, which only sits in that air, is not modelled |
| Boundaries | 6.3.5 and Table E.2: top adiabatic; the underside adiabatic for 60 mm where the frame adjoins; Rse 0.04 exterior, Rsi 0.13 interior, no corner values                                                                  |
| Read-out   | L2D only; Table I.3's U (1.05) is L2D over the 173 mm chain from the gap to the interior face, not over bsb                                                                                                            |

### **11.2 The box cavity**

6.3.5 treats a slightly ventilated shutter box cavity as exterior air with Rs 0.30 on its surfaces, but it refers to 6.4.2.3 and repeats 6.4.2.4.1, both of the radiosity method that Annexes G and H validate. Annex I validates the single equivalent conductivity method, whose rule for a cavity open through a slit over 2 and not over 10 mm is twice the unventilated conductivity (6.4.3.6.1), and Annex I's values are the June 2000 round robin under the 2003 rules, before 6.3.5 existed (2003's Figure D.8 marks e3 as under 10 mm). The box cavity is therefore one slightly ventilated cavity. For the record: with 6.3.5's treatment L2D is 0.1923 (+6.2 %); as a closed cavity 0.1636 (-9.6 %).

**11.3 Results**

**Table 11.2: Case W-8**

| Quantity               | Standard (s.d.) | Thermx               | Difference | THERM 7.8            |
| ---------------------- | --------------- | -------------------- | ---------- | -------------------- |
| L2D W/(m K)            | 0.181 (0.003)   | 0.1834               | +1.3 %     | 0.1834               |
| U over 173 mm W/(m2 K) | 1.05 (0.02)     | 1.060                | +1.0 %     | 1.060                |
| Frame tag              | -               | U 0.6572 over 279 mm | -          | U 0.6572 over 279 mm |
| Error-energy norm      | -               | 6.69 %               | -          | 6.69 %               |

{% hint style="success" %}
**Verdict: Pass.**
{% endhint %}

## 12. Case W-9: PVC Shutter Profile (Figure I.9) <a href="#user-content-12-case-w-9-pvc-shutter-profile-figure-i9" id="user-content-12-case-w-9-pvc-shutter-profile-figure-i9"></a>

### **12.1 Scenario Description**

![Model of Figure I.9](https://2129322768-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FfKJnzF2TwHA3APPbiCpF%2Fuploads%2Fp54gudjTSyUVWzIlBku2%2FModel%20of%20Figure%20I.9?alt=media\&token=d0338307-872c-4307-b47e-59eb1f50ee9f)

**Table 12.1: Case W-9**

| Parameter  | Value                                                                                                                                              |
| ---------- | -------------------------------------------------------------------------------------------------------------------------------------------------- |
| Geometry   | Two identical profiles hooked together, 57 mm wide (b), 7 mm thick; 1 mm skins and webs around four 12 x 5 mm chambers                             |
| Materials  | c PVC 0.17                                                                                                                                         |
| Model      | 15 polygons: 7 solid, 8 cavities                                                                                                                   |
| Cavities   | The four chambers, unventilated. The 1 mm meander in the hook joint divided into four closed rectangles (Figure 13), unventilated                  |
| Boundaries | Adiabatic cuts at both ends; Rse 0.04 below, Rsi 0.13 above; no internal corners                                                                   |
| Judgements | 2017 gives no thickness; 2003's Figure D.9 does (7 mm), and 2017's drawing measures the same. The two profiles touch and are taken as one PVC body |

### **12.2 Results**

**Table 12.2: Case W-9**

| Quantity              | Standard (s.d.) | Thermx              | Difference | THERM 7.8           |
| --------------------- | --------------- | ------------------- | ---------- | ------------------- |
| L2D W/(m K)           | 0.207 (0.001)   | 0.2073              | +0.1 %     | 0.2073              |
| U over 57 mm W/(m2 K) | 3.64 (0.01)     | 3.637               | -0.1 %     | 3.637               |
| Frame tag             | -               | U 3.6367 over 57 mm | -          | U 3.6367 over 57 mm |
| Error-energy norm     | -               | 6.24 %              | -          | 6.24 %              |

{% hint style="success" %}
**Verdict: Pass.**
{% endhint %}

## 13. Case W-10: Wood Frame with Glazing (Figure I.10) <a href="#user-content-13-case-w-10-wood-frame-with-glazing-figure-i10" id="user-content-13-case-w-10-wood-frame-with-glazing-figure-i10"></a>

### **13.1 Scenario Description**

![Model of Figure I.10](https://2129322768-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FfKJnzF2TwHA3APPbiCpF%2Fuploads%2FShcUT5VPbcYQwFzdoYyo%2FModel%20of%20Figure%20I.10?alt=media\&token=cfefe7b0-f3ae-496c-8d50-dabe5a69c3ad)

**Table 13.1: Case W-10**

| Parameter          | Value                                                                                                                                                                                                                                                                                                  |
| ------------------ | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ |
| Geometry           | Figure I.4's frame with the glazing in place of the panel (Annex F.2): two 4 mm panes 20 mm apart (the 18 mm spacer and two 0.5 mm layers), bg = 190 mm                                                                                                                                                |
| Materials          | b softwood 0.13, d EPDM 0.25, f glass 1.0, o gas filling 0.034 (as a solid, giving Ug 1.3), m polysulfide 0.40, h aluminium spacer 160 (walls 0.5 mm), n silica gel 0.13, p polyisobutylene 0.20 (0.5 mm between spacer and each pane)                                                                 |
| Model              | 20 polygons: 17 solid, 3 cavities (as W-4)                                                                                                                                                                                                                                                             |
| Corners (Rsi 0.20) | As W-4                                                                                                                                                                                                                                                                                                 |
| Ψ                  | Ψ = L2D - Uf bf - Ug bg with Uf 1.36, bf 110 mm, Ug 1.3, bg 190 mm (the standard's values)                                                                                                                                                                                                             |
| Judgements         | 2017's vertical chain labels the bottom pane 6 and the bottom gasket 4.5, but the drawing measures 4 and 3 at its own scale, only those fill Figure I.4's 28 mm rebate, and Table I.4 keeps 2003's value: taken as label errors. 2017 names the 0.5 mm layers polyisobutylene (2003 left them unnamed) |

### **13.2 Results**

**Table 13.2: Case W-10**

| Quantity          | Standard (s.d.) | Thermx               | Difference | THERM 7.8            |
| ----------------- | --------------- | -------------------- | ---------- | -------------------- |
| L2D W/(m K)       | 0.481 (0.004)   | 0.4804               | -0.1 %     | 0.4804               |
| Ψ W/(m K)         | 0.084 (0.004)   | 0.084                | 0.000      | 0.084                |
| Frame tag         | -               | U 1.3570 over 354 mm | -          | U 1.3570 over 354 mm |
| Error-energy norm | -               | 9.56 %               | -          | 9.56 %               |

{% hint style="success" %}
**Verdict: Pass.**
{% endhint %}

## 14. Agreement with THERM 7.8 <a href="#user-content-14-agreement-with-therm-78" id="user-content-14-agreement-with-therm-78"></a>

### **14.1 The same model in THERM 7.8**

**Table 14.1: Better Building Thermx Solver 1.0** **against THERM 7.8.80.0**&#x20;

| Case        | THERM 7.8 U over length | Better Building Thermx Solver 1.0 U over length | THERM EEN | Better Building Thermx Solver 1.0 EEN | THERM messages             | Equal |
| ----------- | ----------------------- | ----------------------------------------------- | --------- | ------------------------------------- | -------------------------- | ----- |
| W-1         | 1.6142 over 335 mm      | 1.6142 over 335 mm                              | 7.48 %    | 7.48 %                                | none                       | yes   |
| W-2         | 0.7699 over 338 mm      | 0.7699 over 338 mm                              | 9.86 %    | 9.86 %                                | none                       | yes   |
| W-3         | 1.2257 over 342 mm      | 1.2257 over 342 mm                              | 7.41 %    | 7.41 %                                | none                       | yes   |
| W-4         | 0.9797 over 354 mm      | 0.9797 over 354 mm                              | 4.82 %    | 4.82 %                                | none                       | yes   |
| W-4 variant | 1.0006 over 354 mm      | 1.0006 over 354 mm                              | 5.05 %    | 5.05 %                                | none                       | yes   |
| W-5         | 1.0294 over 392 mm      | 1.0294 over 392 mm                              | 9.75 %    | 9.75 %                                | none                       | yes   |
| W-6         | 2.1686 over 293 mm      | 2.1686 over 293 mm                              | 11.63 %   | 11.63 %                               | maximum meshing iterations | yes   |
| W-7         | 1.0211 over 278 mm      | 1.0211 over 278 mm                              | 4.71 %    | 4.71 %                                | none                       | yes   |
| W-8         | 0.6572 over 279 mm      | 0.6572 over 279 mm                              | 6.69 %    | 6.69 %                                | none                       | yes   |
| W-9         | 3.6367 over 57 mm       | 3.6367 over 57 mm                               | 6.24 %    | 6.24 %                                | none                       | yes   |
| W-10        | 1.3570 over 354 mm      | 1.3570 over 354 mm                              | 9.56 %    | 9.56 %                                | none                       | yes   |

### **14.2 Heat balance**

THERM reports the Exterior tag beside the Frame tag. In a steady state the heat entering through the interior faces equals the heat leaving through the exterior faces; the two agree on every case to within 0.001 W/m, which confirms the solution and the tags cover the whole boundary.

**Table 14.2: Heat flow through the interior and exterior faces in THERM 7.8 (U x length x delta T)**

| Case        | Interior (Frame) W/m | Exterior W/m | Difference W/m |
| ----------- | -------------------- | ------------ | -------------- |
| W-1         | 10.8151              | 10.8153      | 0.0002         |
| W-2         | 5.2045               | 5.2046       | 0.0001         |
| W-3         | 8.3838               | 8.3835       | 0.0003         |
| W-4         | 6.9363               | 6.9362       | 0.0001         |
| W-4 variant | 7.0842               | 7.0844       | 0.0002         |
| W-5         | 8.0705               | 8.0712       | 0.0007         |
| W-6         | 12.7080              | 12.7081      | 0.0001         |
| W-7         | 5.6773               | 5.6772       | 0.0001         |
| W-8         | 3.6672               | 3.6670       | 0.0002         |
| W-9         | 4.1458               | 4.1458       | 0.0000         |
| W-10        | 9.6076               | 9.6074       | 0.0002         |

The differences are the rounding of U to 4 decimals in THERM's dialog.

## 15. Summary of Results <a href="#user-content-15-summary-of-results" id="user-content-15-summary-of-results"></a>

**Table 15.1: Summary**

| Case | Figure                       | L2D standard | L2D Thermx | Difference | Thermx = THERM 7.8 | Verdict               |
| ---- | ---------------------------- | ------------ | ---------- | ---------- | ------------------ | --------------------- |
| W-1  | I.1 aluminium, thermal break | 0.550        | 0.5408     | -1.7 %     | yes                | Pass                  |
| W-2  | I.2 aluminium clad wood      | 0.263        | 0.2602     | -1.1 %     | yes                | Pass                  |
| W-3  | I.3 PVC with steel           | 0.424        | 0.4192     | -1.1 %     | yes                | Pass                  |
| W-4  | I.4 wood                     | 0.346        | 0.3468     | +0.2 %     | yes                | Pass                  |
| W-5  | I.5 roof window              | 0.408        | 0.4035     | -1.1 %     | yes                | Pass                  |
| W-6  | I.6 sliding window           | 0.659        | 0.6354     | -3.6 %     | yes                | Pass (THERM)          |
| W-7  | I.7 PVC fixed frame          | 0.285        | 0.2839     | -0.4 %     | yes                | Pass                  |
| W-8  | I.8 roller shutter box       | 0.181        | 0.1834     | +1.3 %     | yes                | Pass                  |
| W-9  | I.9 PVC shutter profile      | 0.207        | 0.2073     | +0.1 %     | yes                | Pass                  |
| W-10 | I.10 wood frame with glazing | 0.481        | 0.4804     | -0.1 %     | yes                | Pass (Ψ 0.084, exact) |

**Nine of ten Annex I figures are within 3 % of L2D, and the Better Building Thermx Solver 1.0 equals THERM 7.8 on all ten.** The tenth, the sliding window, is 3.6 % below the round robin in THERM 7.8 itself, with the same model, and Thermx reproduces it exactly. The mean difference over the ten figures is -0.8 %, and eight of ten fall within the round robin's own spread of two standard deviations (all but I.2, 0.0028 against 0.002, and I.6).

## Appendix A: Material Property Tabulations <a href="#user-content-appendix-a-material-property-tabulations" id="user-content-appendix-a-material-property-tabulations"></a>

**Table A.1: Table I.2 materials used**

| Key | Material                            | λ W/(m K)                         | Used in                  |
| --- | ----------------------------------- | --------------------------------- | ------------------------ |
| a   | Insulation panel                    | 0.035                             | W-1 to W-8               |
| b   | Softwood                            | 0.13                              | W-2, W-4, W-5, W-10      |
| c   | PVC                                 | 0.17                              | W-3, W-7, W-8, W-9       |
| d   | EPDM                                | 0.25                              | W-1 to W-7, W-10         |
| e   | Polyamide 6.6 with 25 % glass fibre | 0.3                               | W-1                      |
| f   | Glass                               | 1.0                               | W-10                     |
| g   | Steel                               | 50                                | W-3                      |
| h   | Aluminium                           | 160                               | W-1, W-2, W-5, W-6, W-10 |
| i   | Pile weather stripping              | 0.14                              | W-6                      |
| k   | Polyamide                           | 0.25                              | W-6                      |
| l   | Rigid PU                            | 0.25                              | W-6                      |
| m   | Polysulfide                         | 0.40                              | W-10                     |
| n   | Silica gel                          | 0.13                              | W-10                     |
| o   | Gas filling (as a solid)            | 0.034                             | W-10                     |
| p   | Polyisobutylene                     | 0.20                              | W-10                     |
|     | Air cavities                        | THERM's CEN model, emissivity 0.9 | All                      |

## Appendix B: Boundary-Condition Data <a href="#user-content-appendix-b-boundary-condition-data" id="user-content-appendix-b-boundary-condition-data"></a>

| Surface                                                                           | Temperature | Resistance      | THERM film coefficient h = 1 / R |
| --------------------------------------------------------------------------------- | ----------- | --------------- | -------------------------------- |
| Exterior                                                                          | 0 °C        | Rse 0.04 m2 K/W | 25.0 W/(m2 K)                    |
| Interior, plane                                                                   | 20 °C       | Rsi 0.13 m2 K/W | 7.69 W/(m2 K)                    |
| Interior, internal corners (b = d, at most 30 mm)                                 | 20 °C       | Rsi 0.20 m2 K/W | 5.0 W/(m2 K)                     |
| Cut planes, panel end, roof contacts (W-5), shutter box top and frame joint (W-8) |             | Adiabatic       |                                  |

## Appendix C: THERM's CEN Cavity Model against 6.4.3 <a href="#user-content-appendix-c-therms-cen-cavity-model-against-643" id="user-content-appendix-c-therms-cen-cavity-model-against-643"></a>

THERM 7.8's cavity models 1 (CEN) and 2 (CEN ventilated) are a routine in `LBLkeff.dll`, decoded and verified against THERM bit for bit.

| Point                                                                   | Standard (6.4.3)                                                 | THERM 7.8                                                                                          | Same?                                      |
| ----------------------------------------------------------------------- | ---------------------------------------------------------------- | -------------------------------------------------------------------------------------------------- | ------------------------------------------ |
| Equivalent rectangle                                                    | Same area, aspect ratio of the circumscribing rectangle          | d' = sqrt(d A / w) from the rectangularised sides and the true area                                | Yes                                        |
| Convection                                                              | C1 0.025, C2 0.73, threshold b < 5 mm, dT the surface difference | The same constants and threshold (on the equivalent width), dT from the computed side temperatures | Yes                                        |
| Radiation                                                               | hr = 4 σ Tm³ E F                                                 | hr = 4 σ Tm³ / (1/F + 1/E - 1)                                                                     | No: THERM deviation, recorded (Table 16.1) |
| Emissivity                                                              | 0.9 unless stated                                                | The adjoining materials' emissivities, 0.9 here                                                    | Yes                                        |
| Slightly ventilated                                                     | Twice the unventilated conductivity                              | Model 2 is exactly twice model 1                                                                   | Yes                                        |
| Separate cavities at 2 mm, well-ventilated surfaces, corner resistances | Modelling rules                                                  | Drawn by the user                                                                                  | Applied in each case file                  |


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://docs.betterbuilding.io/support-and-training/other-support/testing-and-verification/iso-10077-2-window-frame-validation-report.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.